Frequently asked questions
on infrared touch screens
- Double clicks do not respond well. The solution:
Open the infrared adjustment program to adjust it
and lower down the dB.
- As the infrared touch screen works with infrared.
When sleeves touch the screen, the screen will respond,
too (When a finger touches the screen, the sleeves
may also touch it. So the mouse cursor is likely to
point at the finger point. This is not a problem of
floating).
Frequently asked questions
on surface acoustic wave touch screens
Inaccurate touch of surface acoustic wave touch
screen
¡¤ Please run the correction and adjustment
program for touch screens. (Start-setup-control panel-icon
of acoustic wave screen-button for Caliberate)
¡¤ If it is a newly bought touch screen, please try to
delete the setup and then switch off the computer. Re-install
the setup in five seconds.
¡¤ If this measure does not work, it might be possible
that the reflection fringes were slightly damaged during
the transportation and cannot be completely restored.
You can do the positioning in the counter direction
(as against the direction that the mouse is off the
center point).
¡¤ If the touch screen is not accurate after being used
for a period of time, it is possible that the reflection
fringes on the four sides of the screen or the transducers
are covered by dust. If you use the KA cabinet of our
company, you can use a piece of dry cloth to clean the
surface with industrial alcohol or glass detergent,
and then restart the system. Pay attention not to damage
the upper left, upper right and down right transducers.
If is another type of cabinet, please contact our company's
technology department.
¡¤ If there are water drops or other sticky things on
the touch screen, the screen may misjudge the touches,
which may cause the in accuracy of the screen. Please
just remove the water drops or greasy things.
The surface acoustic wave screen cannot be adjusted
¡¤ If you use a Lenovo computer, and
its pre-installed MOUSEWARE conflicts with the setup
program of the touch screen, please delete this software,
re-start and run the adjustment program.
¡¤ It is possible that the touch screen receives the
operating signal before the computer starts the setup
program for the touch screen, please switch off the
machine, re-start it and readjust it.
¡¤ It is possible that the setup program for the touch
screen has not been properly installed. Please delete
this program and re-install it. (Delete from the control
panel)
¡¤ It is possible that the reflection fringes on the
four sides of the acoustic wave screen, after being
used for a period of time, are covered by lots of dust,
which leads to a failure to adjust. If you use the KA
cabinet of our company, you can open the upper cover,
and rub with a piece of dry cloth. Pay attention not
to damage the upper left, upper right and down right
transducers. Start the computer and adjust the screen.
If you use the other types of cabinets, please contact
the technology department of our company.
No response to the touch on the surface acoustic
wave screen
¡¤ It is possible that the one of the
lines linked with the touch screen - the one linking
the keyboard (taking 5v working voltage from the keyboard
port) - is not linked. Please check this line.
¡¤ It is possible that in the course of touch screen
setup program; the serial port number selected is not
corresponding to the actual number of the linking serial
port. Please unload it and re-install it.
¡¤ It is possible that the compute is domestically made,
and adopts the OEM edition operating system. It has
been adjusted by the factory, causing the non-substandardness
of serial port communication and the incompatibility
with the setup program of the touchscreen. If possible,
please format the hard disk and start the screen after
installing the new setup program.
¡¤ It is possible that the setup program is of too low
an edition, please install the latest setup program
for the touch screen.
¡¤ Check whether any equipment conflicts with serial
port resources. Check hardware and make adjustment.
For instance, some of the installed net cards have their
IRQ defaulted as 3, which is in conflict with IRQ of
COM2. So the IRQ of the net card is changed to an unused
IRQ.
It takes too long a time for the surface acoustic
wave to respond.
¡¤ It is possible that there are moving
water drops on the screen, and the screen responds to
the water drops. Please use a piece of dry cloth.
¡¤ It is possible that the computer is of low grade,
and the time frequency is too low, please change for
a new computer.
No response to the partial touch on the surface
acoustic wave screen
¡¤ It is possible that the reflection
fringes of the touch screen are partially covered. Please
use a piece of dry cloth to clean it.
¡¤ It is possible that the reflection fringes are partially
scratched. It cannot be restored.
Frequently asked questions
about analog resistive touch screen
The mouse of the screen can only move in a small
area or the touch is not accurate
¡¤ It usually appears when the setup
program is first started. Please run the adjustment
program. After the resolution of the touch screen is
changed, the adjustment program must also be run (Start-program)
The mouse always stays at a certain point of the
four sides of the monitor
¡¤ It is because the touch area (The
surface is divided into touch area and non-touch area.
You will get no response if you hit the non-touch area),
is pressed by the casing of the screen or the cabinet,
which means that a certain point has always been touched.
If the casing of the cabinet presses the touch area,
you can adjust the gap between the cabinet and the screen.
If the casing of the screen presses the touch area,
you can try to loosen the screw of the casing. If it
still does not work, please contact the technology department
of our company.
The direction in which the mouse goes is opposite
the direction that the hand touches.
¡¤ This is because the control box of
the touch screen and four lines linked with the touch
screen are connected mistakenly. Please adjust the direction.
No response to the touch
¡¤ Check whether the lines are properly
connected with the touch screen, and whether a line
linking the keyboard port of the computer (taking 5v
working voltage from the keyboard port) is linked or
not.
¡¤ Check the lamp of the control box. If it is not on,
or the red light is on, it indicates that the control
box breaks down. You need to have it replaced.
¡¤ If the circumstances are other than the above mentioned,
please delete the setup program, re-start the computer
and install a new setup program. Or install a higher
edition setup program.
¡¤ Check whether any equipment conflicts with serial
port resources. Check hardware and make adjustment.
For instance, some of the installed net cards have their
IRQ defaulted as 3, which is in conflict with IRQ of
COM2. So the IRQ of the net card is changed to an unused
IRQ. It is possible that the main board of the computer
is not compatible with the control box of the touch
screen. Please change a computer or a main board.
¡¤ Some parts of the screen do not respond to touches
after being used for a fairly long period of time (for
three or four years). The screen might be broken. A
new screen is needed.
Frequently asked questions
about capacitive touch screens
Inaccurate touches on capacitive screens
¡¤ You need to run the screen adjustment
program under the following circumstances (Start-program-Microtouch
Touchware)
- After finishing the installation
of first setup program;
- After changing the resolution
and display mode;
- After changing the display area;
- After adjusting the frequency
o the controller
- When the cursor cannot correspond
with the touch point;
¡¤ After the adjustment is made, the
data after adjustment is stored in the reservoir of
the controller. So there is no need to adjustment screen
after each start.
Touch cannot be made on a certain point of the screen
¡¤ If the touch screen is used for a
fairly long time (usually 5-10 years), the ITO coating
of the screen is likely to be damaged. New touch screen
is needed.
¡¤ If it is a newly installed touch screen, the ITO coating
might have been scratched by ITO coating. Then a new
touch screen is needed.
No response to the touch on capacitive touch screen
¡¤ Check whether the lines to the touch
screen is properly linked. If it is a control card for
exterior hardware box, the box is directly linked with
the cable extending from the touch screen through U-slot.
Through a keyboard converter, link one end with the
computer's keyboard port and the other end with the
keyboard (You must first cut open the rubber cover at
the tip of the serial RS232 before connecting the wire);
put the 5v power source into the connecting part of
serial 232 and put the serial RS232 connector from the
control box into the 9-pin socket of the computer. If
your computer uses a 25-pin socket, please use a 9-25
converter for conversion. If your computer's keyboard
port is a small port from the imported computer, please
buy a converter for the conversion from a large keyboard
to a small keyboard.
¡¤ If it is an in-laid card, check whether the jump is
correct. As the equipment of different customers are
different, their peripherals are different. To avoid
the conflict between touch screens and peripherals,
Mirco Touch offers customers the explanation on the
jump of control card. The explanations are as follows:
¡¤ COM port settings:
Com Port I/O A1 A2 A3 A4 A5 A6
COM1 3F8-3FF ON OFF ON OFF ON OFF
COM2 2F8-2FF OFF ON ON OFF ON OFF
COM3 3E8-3EF ON OFF OFF ON ON OFF
COM4 2E8-2EF OFF ON OFF ON ON OFF
COM5 2E0-3E8 OFF ON OFF ON OFF ON
COM6 2F0-2F8 OFF ON ON OFF OFF ON
COM7 3E0-3E8 ON OFF OFF ON OFF ON
COM8 3F0-3F8 ON OFF ON OFF OFF ON
The combination of Com port and interrupt jumper should
be set in the following ways, except for spcial circumstances.
COM1£>IRQ4 | COM2£>IRQ3 | COM3£>IRQ4 | COM4£>IRQ3
|